Red Laser weak:
This problem is mostly happened on QSS 31. Test pattern isn't black on dark stripes and then going Red, because there is lack of CYAN produced by RED laser gun. Note the very-very weak cyan letter on the edge of the test pattern below. Laser repair required unless you checked AOM Driver and found it bad.

Dead Read Laser:
If above we still could see some weak signs of Red beam (cyan color in negative printing), below we will not see anything. I confused how minilab could print this, without giving error 6073-0001 Synchronous Sensor Error... Anyway, Laser repair is highly recommended.

Red Shift:
Similar to Yellow shift, this problem belongs to QSS32-35 laser units. The Red laser beam becames weaker and synchronouos sensor can not read red marks properly anymore. Three stages are shown below how the connection between Red beam and synchronouos sensor is being lost. Laser repair required.